Regular maintenance of 110kV substation electrical equipment and preventive test equipment
Product list
The serial number A pilot project Project requirement Recommend equipment
1 Transformer test class 35kV high voltage cable, high voltage switch, circuit breaker, PT/CT, 110kV transformer, etc HYG- frequency conversion resonant withstand voltage test device
Cable insulation performance Hyg-5000v insulation resistance tester
Find cable fault Hyg-2013 cable fault tester
2 Transformer test class 50KVA/110KV transformer to ground withstand test HYG- frequency conversion resonant withstand voltage test device
Circuit breaker conductive loop contact resistance measuring range: 0-1999.9 mu Ω
Measuring current: dc ≥200A
Hyg-200a circuit resistance tester
 
Grounding between transformer and switch cabinet Hyg-2571 earth resistance tester
Transformer, voltage transformer ratio and group
Conversion ratio: 1 ~ 9999.9 category: 0 ~ 11
HYG-10000 full automatic variable ratio group tester
All three channels output 10A at the same time Hyg-10a transformer dc resistance tester
5000V Hyg-5000v insulation resistance tester
Breakdown withstand test of insulating oil at 80KV Dielectric strength test of hyg-a insulating oil
Winding deformation Deformation test of hyg-500 transformer winding
Transformer, PT, CT capacitance and dielectric loss measurements
Anti-jamming index: frequency conversion anti-jamming, automatic identification of capacitance, inductance and resistance。
Hyg-8000 anti-interference dielectric loss automatic measuring instrument
3 Switch cabinet test class Switchgear withstand test 95KV Hyg-10kva /100kV withstand test
The insulation performance of the transformer is 5000V Hyg-5000v insulation resistance tester
 
Test the contact resistance at the copper connection 200A Hyg-200a circuit resistance tester
4 Zinc oxide test class Dc parameter test 120KV Hyg-120kv /2mA dc high voltage generator
Ac parameter test HYG-IV zinc oxide arrester
5 PT/CT test class Power frequency withstand voltage HYG- pressure test
CT volt-ampere characteristics, 5% and 10% error curves, variable ratio, polarity, demagnetization, secondary loop, secondary ac withstand, PT volt-ampere characteristics, variable ratio, polarity, secondary ac withstand test functions HYG-1000BTransformer comprehensive tester
Measurement of capacitance and dielectric loss of transformer, PT and CT, anti-interference indicators: frequency conversion anti-interference, automatic identification of capacitance, inductance and resistance. HYG-8000Anti-interference dielectric loss automatic measuring instrument
6 Comprehensive insurance test test class
Integrated protection test: voltage protection, current protection, differential protection, low cycle protection, whole group
Test output 3 phase current, 3 phase voltage single phase current output 0 ~ 40A
Single-phase voltage output 0 ~ 120V
HYG-103Microcomputer relay protection tester
7 Generator set test class Generator rotor ac impedance tester 10kv  18MW
 
 
 
 
8
 
 
 
 
Other test items 
cable HYG-5000VDigital megohm meter
 
On-load tap-changer is the transition time, transition of waveform, transition resistance, the precise measurement of the parameters such as phase synchronism (range: 0.3 ~ 40 Ω precision Ω 0.3 ~ 1 Ω Ω 0.1 mm, 1 Ω ~ 40 Ω + / - 5%) HYG-2009On-load tap changer characteristic tester
Grounding grid measurement at substations of 500kV and below
Current output::AC:5A可选、
Measuring range:0~150Ω(Pile impedance with current)
Power frequency/crossover interference rejection
HYG-5AEarth grid grounding resistance tester
The capacitance of reactive compensation capacitor bank is measured without removing stitches
Capacitance range:0.1μF ~ 2,000μF
HYG-300Automatic capacitance and inductance tester
High voltage switch mechanical characteristic measurement HYG-2008High voltage switch dynamic characteristic tester
Transformer short-circuit impedance and load loss, no-load current and no-load loss measurement
Current measuring range:0.5A~60A
Voltage range:10V~650V
HYG-400ATransformer no-load load characteristic tester
Vacuum degree of vacuum circuit breaker
Measuring range:10-5 ~ 10-1 Pa
HYG-2010Vacuum switch vacuum test
Test voltage measurement (measuring range 0-300kv accuracy 0.5%) HYG-300kVAc-dc voltage divider
CTUpwl check, including 2 2.5m current lines
(Maximum output 5000A gauge head accuracy 1.5%)
HYG-5000AHigh current generator
Wireless detection line phase Angle, frequency, voltage waveform (phase difference measurement accuracy:±
3 degree frequency accuracy:±1Hz;)
HYG-110kVHigh pressure nuclear phase equipment
Frequency response method and plane phase method HYG-IIArrester discharge counter
The measurement temperature control range of gas composition in transformer oil:
Column room: room temperature +15℃ - 399℃
Vaporization chamber: room temperature +30℃ - 399℃
Reformer: room temperature +30℃ - 399℃
Thermal conductivity detector: room temperature +30℃ - 399℃
Hydrogen flame detector: room temperature +30℃ - 399℃
Accuracy: + / - 0.1 ℃
HYG-815ATransformer oil chromatograph
Used for the determination of flash point of liquid that can form surface film of solid suspension of insulating oil under test conditions (measuring range 0-250℃ accuracy ±0.5%) HYG-805Closed flash point meter (automatic)
The acid value of the insulating oil was measured (measurement range: 0.001~0.400mgKOH/g)
Accuracy: acid value between 0~ 0.100mgkoh /g is 0.005mgkoh /g and acid value between 0.100~ 0.400mgkoh /g is 5%)
HYG-806Acid meter
   Dielectric loss of insulating oil: capacitance: 1pF~200pF dielectric loss:
Measurement accuracy: capacitance: ± (0.5%×C+1pF) dielectric loss: ± (1%×D+0.00008) resolution: capacitance: 0.01pf dielectric loss: 1×10-5
HYG-0810Oil dielectric loss tester
SF6 density relay calibration: lockout return value, alarm return value, overpressure return value, alarm value, lockout value, overpressure value (accuracy ±0.25%) HYG-603ASF6Gas density relay calibrator
Detection range: 10 ~ 30 × 1/1 100 ~ 200 × 1/1 300 ~ 500 × 1/1 indication error: ≤±3% HYG-602 High precision SF6 gas leak detector
Moisture content in SF6 gas was measured
The dew point:
Measurement range: -60 ℃ ~ +20 ℃
Measurement accuracy: ±0.5℃ (-60℃ ~ +20℃)
Response time (+20℃) : < 3 min
HYG-606 SF6Intelligent moisture meter
 
Insulation resistance measurement multimeter
Test voltage measurement QJWheatstone bridge
Dc resistance measurement QJ44Double bridge
Dc resistance measurement HYG-3000Digital double - clamp phase voltammeter
Current and voltage loop check Phase sequence table
Indicates the phase sequence of the three-phase sinusoidal ac power supply Clamp ammeter
Current measurement HYG-Dc stabilized voltage stabilized current power supply
Secondary load measurement HYG-Transformer secondary load tester